The probe HCF100 is a Semiconductor gas sensing unit with protection grade IP55, that connected to a BEINAT’S industrial type control units.
Allow to individuate presence of: TOXIC GASES such as:
Refrigerant FREON.
The probe is managed by a microprocessor that besides to furnish the central to which is connected with an alarm signal, allows to make an auto-diagnosis and then an AUTOMATIC CALIBRATION, to have constantly during time maximum sensing precision. The auto-calibration permit the probe to adapt in difficult ambience and at variable temperature, avoiding false alarms due to anomalous events.
In the probe is present a linear exit 0 ÷ 300ppm, functioning with standard 4 ÷ 20 mA.

Compatible control units GS100M, GS300-Mc, BX150, BX180, BX280 BX444-Mc, BX449F, BX308xp, BX316xp

Power Supply: 12÷24 V. dc ± 10%
Power Demand: 1,5 W max @13,8V
Main Alarm Relays: 10A SELV
Sensor: Semiconductor
Alarm Threshold: At 300ppm
Input Signal: 4 ÷ 20 mA
Data transmission: Not present
Service Port: Present
Test Phase Duration: 90 seconds
Functioning Temperature: -10°C to +50°C
Degree of Protection: IP55
Compatible control units: whole range
Case and Size: ABS-78x114x58
Packaging: 197x122x67
Weight: 270 grams about