Digital Pressure Analyzer BEINAT
  • Digital Pressure Analyzer BEINAT MD80
  • Digital Pressure Analyzer BEINAT
  • Digital Pressure Analyzer BEINAT
  • Digital Pressure Analyzer BEINAT MD80
  • Digital Pressure Analyzer BEINAT MD80
  • Digital Pressure Analyzer BEINAT MD80

MD80 Digital Pressure Analyzer

Cod. MD80 - Digital Pressure Analyzer

Description of the TEST programs according to UNI

UNI 7129 Less than 35 kW Tightness test
UNI 11147 Pressure plant tightness test
UNI 11137 Calculation of liter leak automatic
UNI 11137 Calculation of liter leak manual
UNI 11137 Tightness test for max. 18 dm^3 systems
UNI 11137 Valve tightness testa
UNI 11137 Mechanical tightness
UNI 10738 Ventilation and change air in rooms
UNI 10845 Depression test of chimneys draft
UNI 10845 Pressure tightness of chimneys draft
UNI 11528 6a species > of 35kW for external pipes
UNI 11528 6a species > of 35kW for underground pipes
UNI 11528 7a species > of 35kW for external pipes
UNI 11528 7a species > of 35kW for underground pipes

MEASUREMENTS internal sensors

Reading and direct tests up to 10 Pa
Reading and direct tests up to 1000 mbar
Temperature up to 100 ° C
Barometric pressure

MEASUREMENTS external sensors
Reading and direct tests up to 45 bar
Temperature up to 500 ° C
Pressure recorder in gas pipes
Registration of a networked pressure

SETTINGS
Set time and date
Set technician data
Entry phonebook, customer data, even from memory
Change password o disabled
Enable or disable of barometric pressure
The battery status read control
Selection of the graphic display
Connection settings with PC
Set language: IT-EN-FR-ES
Selecting the internal pressure max 10 Pa
Selecting the internal pressure max 500 mbar
Selecting the external pressure transducer, 10/45 bar
Selecting the size of the test syringe
Selecting thermometer: Internal -20+100 °C
Selecting thermometer “2” : Esternal -50+1000 °C
Selecting bluetooth or IR printer

PRINTER
Control and printer start up
DATA TRANSMISSION & MEMORY
Bluetooth Data transmission
IR data transmission
Customer store from micro SD to internal phonebook
Stored data transmission of the plants inspected,
Deleting stored data

COMMUNICATION PORTS
2 Thermocouple temperature type K ports
1 Micro USB port for PC connection, battery charger
1 Micro HDMI port for connecting accessories
1 Micro SD CARD for storing data

INFORMATIONS

Product, serial number, revision expiration date, etc..
Laws and decrees presentation
Diameters and volume of the pipes


CONVERTER
Unit of measure.


CALCULATOR
Mathematic operations

 Download pdf file

MD80